Geocache Description:

Sorlaxin muistoa kunnioittaen

Sorlax sähköasema on pienen pieni johtolähtö Vaasan Runsorissa. Sorlax asema esittelee relesuojauksen uusimmat uutuudet.
In memory of Sorlax

Sorlax substation is a tiny line feeder in Runsor industrial park. Sorlax substation introduces the state of the art in relay protection.

Differentiaalirele.
Differential relay

Sorlax sähköasema on pienen pieni johtolähtö Vaasan Runsorissa. Sorlax sähköaseman tarkoitus on osaltaan vähäsen raottaa tarkoin varjellun ja mystisenkin relesuojausmaailman esirippua niin, että suuri geokätköyhteisö voisi saada pienen käsityksen siitä, minkä parissa Sorlax on työskennellyt lähes koko työuransa. Alallaan kovasti arvostettu asiantuntija ja loistava työtoveri siirtyy muiden harrastusten pariin tai ehkä jopa viettämään eläkepäiviä. Olkoon siis tämä kätkö läksiäislahja.

Suojarele on laite, joka valvoo sähköverkon kuntoa ja tarvittaessa ohjaa katkaisijaa erottaen vikaantuneen osan verkosta niin, että vika ei pääse leviämään koko verkon kattavaksi.
Suuri osa suomen jakeluverkosta on avojohtoverkkoa jossa tyypillisimmät viat lienevät salamana iskun ja eläinten aiheuttamat (tyypillisesti suuret muuttolinnut) valokaaret (kaksi- tai kolmivaiheinen oikosulku maakosketuksella tai ilman), tai kasvillisuuden aiheuttama maasulku (puun kosketus linjaan).
Tyypillisiä suojareleitä ovat ylivirta- ja maasulkurele, yli- ja alijänniterele sekä yli- ja alitaajuusrele. Suojareleet voivat olla myös huomattavasti sofistikoituneempia kuten esimerkiksi, moottori- tai generaattorisuoja, differentiaali- eli vertorele tai distanssirele. Nykyaikaiset suojareleet sisältävä useita eri suojausfunktioita yhdessä ja samassa laitteessa.

Ensimmäiset suojareleet olivat puhtaasti sähkömekaanisia laitteita, kuten vaikka yllä olevan kuvan differentiaalirele. Elektroniikan kehityksen myötä seuraavaa relesukupolvea kutsuttiin staattiseksi releeksi koska releessä ei enään ollut liikkuvia osia kuten sähkömekaanisissa releissä. Staattiset releet olivat tyypillisesti analogiaelektroniikalla toteutettuja kun taas digitaaliset releet oli toteutettu digitaalielektroniikalla. Mikroprosessorien kehittyessä myös releet kehittyivät ja muuttuivat nykyisen kaltaisiksi numeerisiksi releiksi.
Nykyaikainen suojarele tekee melkein mitä tahansa, paitsi ei keitä aamupuuroa. Nykyaikaiseen suojareleeseen on integroitu tarvittavien suojausfunktioiden lisäksi kattava itsevalvonta, ohjaustoiminnot, asematason kommunikaatio muiden releiden kanssa ja kommunikaatio kaukokäyttöön. Lisäksi suojarele voi sisältää erilaisia mittaustoimintoja kuten tehon- ja energian mittaus.

Onnea etsintään!


Substation Sorlax is a tiny line feeder in Runsor industrial park in Vaasa. Sorlax substation is build in order to clarify mysterious field of relay protection. Now everyone in geocaching community have an opportunity to have a little flavor of topict that Sorlax has worked on all his career. A highly regarded relay protection specialist and great colleague of mine is now heading on new challenges as retiree ... or something. Let this cache be a gift for Sorlax on his last working day.

The protective relay is a device to monitor electrical network and to initiate a trip command for the circuit breaker in case of fault detected in the network. An unisolated fault in the network may propagate and escalate such a way that a large black out will be faced. By isolating the faulty part of the network such a balck out situation can be prevented.
Most of the distribution network in Finland is so called over head line. This is especially true outside cities. Most typical faults on the over head line are arc faults induced by a lightning strike or a fault induced by animals on the line. Also a fault called earth fault is typical on over head lines due to plantation in close contact to the line.
Typical relays used to protect distribution network are over current and earth fault relay, under and over voltage relay, under and over frequency relay. Some relays are much more sophisticated like motor and generator protection relays and differential and distance relays. Modern relays usually combines several protection function to a one single device.

Protective relays of the first generation were all electhro mechanical devices. The picture above shows electhro mechanical differential relay. In course of micro electronics development protective relays developed too. The next generation of the relays we called as static relay due to lack of moving mechanical parts. Static relays were implemented by utilizing analogical electronics. In course of further development digital electronics and finally micro controllers (micro processors) found their way into protective relays. In digital era protective relays were called as digital relay while the latest generation of the relays are named as numerical relay. The protective relays of today are capable to do almost anything except serving a breakfast. Along protection functions many other functions are integrated in modern relays. Relays are capable to communicate between relays in substation and to control center level (Scada systems). Many measurement functions like power and energy measurements can be integrated in modern relays.

Good luck!